logo

FM200 Gas System Cylinder Without Pollution For Battery Room

1 Set
MOQ
Dapat dinegosiasikan
harga
FM200 Gas System Cylinder Without Pollution For Battery Room
fitur Galeri Deskripsi Produk Quote request suatu
fitur
Spesifikasi
Model TIDAK.: QMP32/2.5, QMP40/4.2, QMP52/2.5, QMP70/4.2, QMP100/4.2, QMP106/2.5, QMP120/4.2, QMP147/2.5, QMP150/4
Volume (l): 32 ,40 ,52 , 70, 100 ,106 ,120, 147 ,150, 180
Tekanan Penyimpanan: 4.2MPA; 2.5mpa
Diameter internal: 300, 350, 400
Warna: Merah
Menyoroti:

FM200 gas cylinder for battery room

,

pollution-free FM200 cylinder

,

FM200 fire suppression cylinder

Informasi dasar
Tempat asal: Cina
Nama merek: Air Giant
Sertifikasi: CAL,CMA,CNAS,ILAC-MRA,CCC
Nomor model: QMP32/2.5, QMP40/4.2, QMP52/2.5, QMP70/4.2, QMP100/4.2, QMP106/2.5, QMP120/4.2, QMP147/2.5, QMP150/4
Syarat-syarat pembayaran & pengiriman
Kemasan rincian: Kotak luar kayu lapis dengan tas gelembung atau kertas
Waktu pengiriman: 10-15 hari kerja
Syarat-syarat pembayaran: L/C,D/P,T/T,Western Union,Paypal,kartu kredit
Menyediakan kemampuan: 28000 set per minggu
Deskripsi Produk

FM200 Gas System Cylinder Without Pollution For Battery Room


Description


The table shows the specific parameters of several conventional bottles of different sizes

NO.

Specifications

4.2MPa system

1

Capacity

40Ltr,70Ltr,100Ltr,120Ltr,150Ltr,180Ltr

2

Device model

QMP40/4.2, QMP70/4.2, QMP100/4.2, QMP120/4.2, QMP150/4.2, QMP180/4.2

3

Storage pressure

4.2MPa

4

Max. working pressure

5.3 MPa (50℃)

5

Min. working pressure

3.6MPa (0℃)

6

 Filling rate

FM200≤1.0 kg/L / Novec1230≤1.42kg/L

7

Discharge time

≤10s

8

Power

DC24V/1.5A

9

Nitrogen driving device

6.0±1.0MPa

10

Storage surroundings

Temperature:0~50°C

Relative humidity:<97%

11

Proportion

≤800m2

12

Volume

≤3600m3


Components


The bottle part is composed of steel cylinder and cylinder valve

                   

FM200 Gas System Cylinder Without Pollution For Battery Room 0   FM200 Gas System Cylinder Without Pollution For Battery Room 1    FM200 Gas System Cylinder Without Pollution For Battery Room 2


Application


The pipe network type fm200 fire suppression system is suitable for a lot of places and several kinds of fires. The followings are some examples for customer as reference:

 

- Telecommunications and data processing

- Switch gear rooms

- Military applications and cell sites

- High-tech medical application

- Computer rooms

- Telecommunication centers

- Records and data archives

- Testing/imaging equipment

- Reference material

- Chemical laboratories


FM200 Gas System Cylinder Without Pollution For Battery Room 3


Package


We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.


FM200 Gas System Cylinder Without Pollution For Battery Room 4

Rekomendasi Produk
Hubungi kami
Kontak Person : Mr. Missaya Lu
Tel : +86 188 1945 1181
Karakter yang tersisa(20/3000)